{"product_id":"abs-30-cu-ft-capacity-premier-laboratory-refrigerator-solid-door-abt-hc-30r-p","title":"ABS 30 cu. ft. Capacity Premier Laboratory Refrigerator Solid Door ABT-HC-30R-P","description":"\u003ch2\u003eABS 30 cu. ft. Capacity Premier Laboratory Refrigerator Solid Door ABT-HC-30R-P\u003c\/h2\u003e\n\u003cp\u003eDesigned for reliable and eco-conscious laboratory storage, this 30 cu. ft. touchpad laboratory refrigerator offers versatile performance for lab environments. Its temperature control is powered by microprocessor technology and maintains tight temperature uniformity with an adjustable operating range of 2°C to 10°C. Enjoy a user-friendly touchpad controller and a robust alarm system including audible and visual temperature alarms, door ajar alarms, sensor error alarms, and power failure alarms—all with battery backups to keep alarms running during outages. Utilizing hydrocarbon refrigerants, this unit meets EPA SNAP compliance, protecting environmental safety. It features a durable white powder-coated steel exterior, with a keyed door lock for added security. This unit offers 30 cubic feet of spacious storage and five adjustable shelves for versatile organization. With a low energy consumption and environmental benefits, the ABT-HC-30R-P is an efficient and next-level solution for diverse laboratory applications.\u003c\/p\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eStorage capacity (cu. ft)\u003c\/td\u003e\n\u003ctd width=\"298\"\u003e30 Cu. Ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eDoor\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eOne solid swing, right hinged; stainless steel door handle; magnetic door gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eShelves\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eFive adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eDrawers\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eNon-applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eMounting and Installation\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eCaster platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eInterior lighting\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eNon-applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eAirflow Management\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eForced draft circulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eExternal probe access\u003c\/td\u003e\n\u003ctd width=\"298\"\u003e3\/4″ probe access port on rear wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eInsulation\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eEPA compliant high density urethane foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eExterior materials\u003c\/td\u003e\n\u003ctd width=\"298\"\u003ePowder coated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eAccess control\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eKeyed Door Lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eGeneral warranty\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eTwo (2) year parts and labor warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eCompressor warranty\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eFive (5) year compressor parts warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eProduct Weight (lbs)\u003c\/td\u003e\n\u003ctd width=\"298\"\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eShipping Weight (lbs)\u003c\/td\u003e\n\u003ctd width=\"298\"\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eRated Amperage\u003c\/td\u003e\n\u003ctd width=\"298\"\u003e3.1 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003ePower Plug\/Power Cord\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eNEMA 5-15P plug, 6 ft long cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eFacility Electrical Requirement\u003c\/td\u003e\n\u003ctd width=\"298\"\u003e110 – 120V AC, 15A breaker, NEMA 5-15 receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"141\"\u003eAgency Listing and Certification\u003c\/td\u003e\n\u003ctd width=\"298\"\u003eUL listed per UL 60335-1 and UL 60335-2-89 standards; c UL listed per CSA C22.2\u003cbr\u003eNo. 120 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eUniformity (Cabinet air)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e+\/- 1.6°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eStability (Cabinet air)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e+\/- 1.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eMaximum temperature variation\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e3.6 °C Total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003e(Cabinet air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eEnergy Consumption (KWh\/day)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e\u0026lt; 1.7 KWh\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eAverage Heat Rejection (BTU\/hr)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e520 BUT\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003ePull down time to nominal operating temp\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"279\"\u003e\u0026lt;35 min (empty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eWidth (in.)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e35.75″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eDepth (in.)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e35.5″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eHeight (in.)\u003c\/td\u003e\n\u003ctd width=\"279\"\u003e76.5″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd width=\"279\"\u003eEPA SNAP compliant R600a Isobutane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemp Controller\u003c\/h3\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eController technology\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eMicroprocessor temperature controller with variable frequency compressor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eBattery Backup\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eTemperature display and alarm only (no active cooling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eDisplay technology\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eDigital Temperature Display, Sample simulated digital temperature display; .1° Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eNon-applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eData Transfer\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eNon-applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eTemperature Setpoint Range Notes\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eMinimum temperature limited to avoid freezing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eAdjustable Temperature Range\u003c\/td\u003e\n\u003ctd width=\"472\"\u003e2°C to 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eExternal alarm connection\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eRemote alarm contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eAlarms\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eAudible and visual high and low temperature alarms, Remote alarm contacts, Sensor error alarm, Power failure alarm, Resettable 1-point Min\/Max History, Alarm validation (audible, visual, and remote alarm), Alarm mute with ring back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eDisplay Probe\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eProduct simulator bottle with glass bead media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003eDisclaimers\u003c\/td\u003e\n\u003ctd width=\"472\"\u003eRefrigerator requires a minimum 4” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Documents\u003c\/strong\u003e\u003c\/p\u003e","brand":"American BioTech Supply","offers":[{"title":"Default Title","offer_id":43657523560526,"sku":"ABT-HC-30R-P","price":6349.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2198\/6126\/files\/ABT-HC-30R-P-Ext-Image_960x960_efa1052f-6798-4504-83de-1300ca5d8138.jpg?v=1776803036","url":"https:\/\/microscopemarketplace.com\/products\/abs-30-cu-ft-capacity-premier-laboratory-refrigerator-solid-door-abt-hc-30r-p","provider":"Microscope Marketplace","version":"1.0","type":"link"}